DHex v5.0.0.0

  • Internal code refining for Heat Exchanger Suite (HExS) publish automation
  • Enhanced material thermal conductivitues database and added more material thermal conductvities.
  • Added new setting to check for software updates on start
  • Added physical properties PProps internal database containing 500 fluids

DHex v4.0.0.0

  • Maintenance release addressing software licensing on new activation server

DHex v3.1.05

  • Maintenance release
  • fixed bug to address failing to calculate the thermal capacity ratio
  • fixed bug to address failing to calculate the number of transfer unit
  • fixed bug to address failing to calculate pressure drop in annulus side

DHex v3.1.0.4

  • Maintenance release

DHex v3.1.0.3

  • Added used hydraulic diameter for Nusselt number calculation. This feature can be accessed through the software setting screen
  • Minor fixes to interface

DHex v3.1.0.2

  • Software upgrade to Microsoft dot Net 4.8 Framework
  • Fixed bug affecting retrieving film heat transfer coefficient user database entries
  • Added water and steam properties
  • Added check for software update

DHex v3.1.0.1

  • Fixed bug affecting retrieving Nusselt user correlations when user is using comma for decimal point separator

DHex v3.1.0.0

  • Maintenance release addressing software licensing on new activation server
  • Added license information screen can be accessed from Help menu

DHex v3.0.0.3

  • Maintenance release addressed software digital signature and end user license agreement

DHex v3.0.0.2

  • Ability to designate Nusselt user correlations to inner pipe or outer pipe side
  • Plot temperature profile for hot and cold sides, check temperature cross chart
  • Multi case feature will now save cases in a case list and reload a case upon request during run time. 

DHex v3.0.0.1

  • Maintenance release

DHex v3.0.0.0

  • Software upgrade to Microsoft dot Net 4.6 Framework
  • New user interface
  • Added pumping power calculation
  • Add your own Nusselt correlations to use in software calculations
  • Added Unit converter includes 23 measurements units with 200-unit conversion
  • Added Input Consistency check – to reduce input errors related to decimal point separator
  • Some enhancement to results display
  • Added Re-Save feature faster saving for edited files
  • Added ability to enter heat transfer coefficient on both inner pipe side and outer pipe side
  • Ability to enter Heat Duty
  • Ability to calculate unknown exit temperatures on both sides or any two temperatures on both sides.
  • Ability to add multiple cases to one results grid.
  • Ability to add heat transfer coefficients in a user database table and load it during calculation.
  • Added the following Nusselt number correlations:
  • – Petukhov and Popov
  • – Sleicher and Rouse
  • – Gnielinski
  • – Prandtl
  • – Modified Dittus-Boelter
  • Pressure drop friction factor chart under finned tube option has been removed and calculation of this friction factor is now done by the software
  • Enhance summary of results presentation

DHex v2.1.0.0

  • Added Ability to export results to Engineering Datasheet format (To Microsoft Excel)

DHex v2.0.0.0

  • Enhanced User Interface
  • Added support for WeBBusterZ Physical properties database
  • Added fouling factors
  • Fixed some small programming bugs

DHex v1.0.0